Modelling and Design of Neutral Point Clamped Inverter for Mitigating Low Harmonics Ripple Case Study for Over Modulation Mode

dc.contributor.guideMahendra Lalwani
dc.coverage.spatial
dc.creator.researcherBharat Modi
dc.date.accessioned2024-02-22T08:22:05Z
dc.date.available2024-02-22T08:22:05Z
dc.date.awarded2023
dc.date.completed2023
dc.date.registered2017
dc.description.abstractOver modulation phenomenon has been investigated through several PWM (Pulse Width Modulation) techniques in NPC (Neutral Point Clamp Inverter). However, due to non- linear characteristics and a severe low harmonics ripples, it has not been used in closed-loop control. Nevertheless, the over-modulation index, m1:15, can be achieved by injection of the third harmonic in STPWM (sine triangle pulse width modulation) without pulse dropping. The inverter has to work in over modulation region to utilize the maximum DC bus voltage is require reduction in the low harmonic ripple. For the reduction of THD (Total Harmonics Distortions), grid contributes to supply as AHF(Active Harmonics Filter) used and the modulation index is taken more than 1.15. After doing the investigation on several PWM techniques, it is concluded that STPWM with third harmonic injection is more suitable with specified modulation indexes. newline newlineIt has been observed that low-frequency harmonics get generated in over- modulation region due to pulse dropping. If friendly harmonics get injected (which are opposite in polarity with low harmonic and are in the same polarity with fundamental frequency) in the system, then these low harmonic can get eliminated with higher modulation index. A compensator in the present work has been designed that is connected to the NPC inverter. In this compensator, simple clipping circuits with grid and DC sources are used. This compensator has two tasks. First, to detect the low order harmonics and second to add desired friendly harmonics. The performance of the compensator gets verified by simulation results and mathematical models analysis, shown in further sections of this thesis. The additional advantages of this compensator are the maximum utilization of DC bus voltage during the mismatch of the grid and the solar inverter output voltages. newline newline
dc.description.note
dc.format.accompanyingmaterialDVD
dc.format.dimensions
dc.format.extent32.6 mb
dc.identifier.urihttp://hdl.handle.net/10603/546734
dc.languageEnglish
dc.publisher.institutionElectrical Engineering
dc.publisher.placeKota
dc.publisher.universityRajasthan Technical University, Kota
dc.relation
dc.rightsuniversity
dc.source.universityUniversity
dc.subject.keywordEngineering
dc.subject.keywordEngineering and Technology
dc.subject.keywordEngineering Electrical and Electronic
dc.titleModelling and Design of Neutral Point Clamped Inverter for Mitigating Low Harmonics Ripple Case Study for Over Modulation Mode
dc.title.alternative
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 5 of 14
Loading...
Thumbnail Image
Name:
80_recommendation.pdf
Size:
192.52 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
abstract.pdf
Size:
483.95 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
annexures.pdf
Size:
7.63 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
chapter-1.pdf
Size:
3.09 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
chapter-2.pdf
Size:
8.12 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: