Advanced Fault Detection and Protection Strategies For UPFC Compensated Power Networks

dc.contributor.guidePatidar, Ram Dayal and Biswal, Sandeep
dc.coverage.spatial
dc.creator.researcherPanday, Ajay
dc.date.accessioned2025-01-15T11:09:42Z
dc.date.available2025-01-15T11:09:42Z
dc.date.awarded2025
dc.date.completed2024
dc.date.registered2019
dc.description.abstractTransmission line faults are the unavoidable key and intricate barrier for the safe and newlinestable power system operation. Although traditional distance and differential protection strategies newlineare widely adopted to protect, but, may experience difficulties due to incorporation of FACTS newlinecontrollers, integration with large scale renewable and presence of fault current limiters. Further, newlineTransmission lines may experience a cascaded outage if such relays malfunction. This thesis newlinefocuses on the single and both ended protection schemes for UPFC compensated transmission line newlineconsidering the effect of SFCLs and WFs. newlineThe non-linear operation of the UPFC results transient components in the voltage and newlinecurrent phasors. The actual information gets corrupted due to non-linear operating modes of newlineUPFC. This would result malfunction of various well-known unit protection schemes. Instead of newlinegoing any phasor or time domain based approach, a signal decomposition based energy operator is newlinederived which can capture the transient information. The two end current information is utilized to newlineobtain this energy index which helps to detect the fault and proper classification of the fault phase. newline Large-scale doubly fed induction generator-based wind farms (DFIG-WFs) have a newlinesignificant impact on transmission line conventional differential schemes due to their dynamic newlinefault current characteristics, transient behavior, and fluctuating output power. Additionally, the newlinecombined impacts of the FACTS controller and WFs negatively impact a number of unit newlineprotection strategies. STMPM, a data-driven approach, is presented to locate the error and then newlinedevelop the disturbance detection index (DDI) in order to complete this job. newlineUPFC and DFIG-WFs are two components that may add to fault current. The superior newlinetechnical performance of Superconducting Fault Current Limiters (SFCLs) in limiting fault newlinecurrents makes their use crucial in such a situation. The addition of SFCL, however, would make newlinethings more difficult for the current disturbanc
dc.description.note
dc.format.accompanyingmaterialNone
dc.format.dimensions
dc.format.extent174
dc.identifier.researcherid0000-0001-7027-1488
dc.identifier.urihttp://hdl.handle.net/10603/615241
dc.languageEnglish
dc.publisher.institutionDepartment of Electrical and Electronics Engineering
dc.publisher.placeRaigarh
dc.publisher.universityO.P. Jindal University
dc.relation
dc.rightsuniversity
dc.source.universityUniversity
dc.subject.keywordcurrent transformer saturation
dc.subject.keywordDFIG-WFs
dc.subject.keywordDifferential protection
dc.subject.keywordEngineering
dc.subject.keywordEngineering and Technology
dc.subject.keywordEngineering Electrical and Electronic
dc.subject.keywordsingle pole tripping
dc.subject.keywordUPFC
dc.titleAdvanced Fault Detection and Protection Strategies For UPFC Compensated Power Networks
dc.title.alternative
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 5 of 11
Loading...
Thumbnail Image
Name:
01_title.pdf
Size:
46.77 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02_prelims pages.pdf
Size:
121.68 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_abstract.pdf
Size:
27.87 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_chapter 1.pdf
Size:
67.26 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
06_chapter 2.pdf
Size:
59.24 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: